Analytické řešení aplikátorů pro mikrovlnné vysoušení textilií pomocí metody mnohonásobných odrazů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F07%3A03131960" target="_blank" >RIV/68407700:21230/07:03131960 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analytical Solutions to the Applicators for Microwave Textile Drying by Means of Zigzag Method
Popis výsledku v původním jazyce
This paper described the Zigzag method for solving microwave applicators for drying of textile materials, which is based on the solving transfer characteristics of waveguide with discontinuities. We can describe the wet textile as discontinuity by meansof three quantities: the size of reflection coefficient |rho|, its phase angle phi and phase angle ? of transmission coefficient ?. The size of the transmission coefficient is defined by known relation ??* = 1- |rho|2 which results from the principle ofconservation of energy. We created diagram of EM waves inside this structure and reached the resulting expression, which is used for calculation of electric field strength in the plane of drying textile. This quantity depends on electrical characteristics of wet textile such as permittivity and loss factor. Measurements of these dielectric properties for the coburg is complicated and this method makes it possible to solve our problem with dielectric parameter
Název v anglickém jazyce
Analytical Solutions to the Applicators for Microwave Textile Drying by Means of Zigzag Method
Popis výsledku anglicky
This paper described the Zigzag method for solving microwave applicators for drying of textile materials, which is based on the solving transfer characteristics of waveguide with discontinuities. We can describe the wet textile as discontinuity by meansof three quantities: the size of reflection coefficient |rho|, its phase angle phi and phase angle ? of transmission coefficient ?. The size of the transmission coefficient is defined by known relation ??* = 1- |rho|2 which results from the principle ofconservation of energy. We created diagram of EM waves inside this structure and reached the resulting expression, which is used for calculation of electric field strength in the plane of drying textile. This quantity depends on electrical characteristics of wet textile such as permittivity and loss factor. Measurements of these dielectric properties for the coburg is complicated and this method makes it possible to solve our problem with dielectric parameter
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F03%2FH086" target="_blank" >GD102/03/H086: Nové pojetí a koordinace výuky doktorandů v radioelektronice a souvisejících oborech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2007 Prague - Proceeding od Progress In Electromagnetics Research Symposium
ISBN
978-1-934142-02-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
317-320
Název nakladatele
The Electromagnetics Academy
Místo vydání
Cambridge, MA
Místo konání akce
Praha, ČVUT FEL
Datum konání akce
27. 8. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—