Two Minimal Problems for Cameras with Radial Distortion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F07%3A03135486" target="_blank" >RIV/68407700:21230/07:03135486 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Two Minimal Problems for Cameras with Radial Distortion
Popis výsledku v původním jazyce
Epipolar geometry and relative camera pose computation for uncalibrated cameras with radial distortion has recently been formulated as a minimal problem and successfully solved in floating point arithmetics. The singularity of the fundamental matrix hasbeen used to reduce the minimal number of points to eight. It was assumed that the cameras were not calibrated but had same distortions. In this paper we formulate two new minimal problems for estimating epipolar geometry of cameras with radial distortion. First we present a minimal algorithm for partially calibrated cameras with same radial distortion. Using the trace constraint which holds for the epipolar geometry of calibrated cameras to reduce the number of necessary points from eight to six. We demonstrate that the problem is solvable in exact rational arithmetics. Secondly, we present a minimal algorithm for uncalibrated cameras with different radial distortions. We show that the problem can be solved using nine points in two vie
Název v anglickém jazyce
Two Minimal Problems for Cameras with Radial Distortion
Popis výsledku anglicky
Epipolar geometry and relative camera pose computation for uncalibrated cameras with radial distortion has recently been formulated as a minimal problem and successfully solved in floating point arithmetics. The singularity of the fundamental matrix hasbeen used to reduce the minimal number of points to eight. It was assumed that the cameras were not calibrated but had same distortions. In this paper we formulate two new minimal problems for estimating epipolar geometry of cameras with radial distortion. First we present a minimal algorithm for partially calibrated cameras with same radial distortion. Using the trace constraint which holds for the epipolar geometry of calibrated cameras to reduce the number of necessary points from eight to six. We demonstrate that the problem is solvable in exact rational arithmetics. Secondly, we present a minimal algorithm for uncalibrated cameras with different radial distortions. We show that the problem can be solved using nine points in two vie
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Omnivis 2007: Workshop on Omnidirectional Vision and Camera Networks and Non-classical Cameras
ISBN
978-1-4244-1630-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Omnipress
Místo vydání
Madison
Místo konání akce
Rio de Janeiro
Datum konání akce
20. 10. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—