Využití vlnkové transformace pro extrakci příznaků z EKG
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A03144636" target="_blank" >RIV/68407700:21230/08:03144636 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using Wavelet Transform for Feature Extraction from ECG Beat
Popis výsledku v původním jazyce
Long term holter monitoring is widely applied to patients with heart problems such as arrhythmias. The primary task of computer aided systems in holter ECG evaluation is to distinguish between different beat types. In this work we investigate the use ofwavelet packets as a mean to extract features capable of providing the information needed by a classifier for discrimination between Ventricular (V) and Normal beats (N). We designed approach for feature extraction based on wavelet packets and template matching. We used MIT database for test of this approach. The database was divided into to subsets (testing and validation) and we obtained sensitivity 97,7% and 91,9%, specificity 95,1% and 87,1%, overall accuracy 96,3% and 90,4% on the first subset andsecond subset respectively.
Název v anglickém jazyce
Using Wavelet Transform for Feature Extraction from ECG Beat
Popis výsledku anglicky
Long term holter monitoring is widely applied to patients with heart problems such as arrhythmias. The primary task of computer aided systems in holter ECG evaluation is to distinguish between different beat types. In this work we investigate the use ofwavelet packets as a mean to extract features capable of providing the information needed by a classifier for discrimination between Ventricular (V) and Normal beats (N). We designed approach for feature extraction based on wavelet packets and template matching. We used MIT database for test of this approach. The database was divided into to subsets (testing and validation) and we obtained sensitivity 97,7% and 91,9%, specificity 95,1% and 87,1%, overall accuracy 96,3% and 90,4% on the first subset andsecond subset respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1ET201210527" target="_blank" >1ET201210527: Znalostní podpora diagnostiky a predikce v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Analysis of Biomedical Signals and Images; Biosignal 2008 proceedings
ISBN
978-80-214-3613-8
ISSN
1211-412X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
VUTIUM Press
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
29. 6. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—