Použití proudového zdroje pro kalibraci automatického testovacího zařízení
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A03146039" target="_blank" >RIV/68407700:21230/08:03146039 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00177016:_____/08:#0000414
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of a Current Source for Calibrating an Automatic Transformer Test Set
Popis výsledku v původním jazyce
This paper describes an innovative procedure for calibrating sets for evaluating instrument current transformer (ICT) errors. The innovation lies in the use of a current source for generating a measured current. There is an adjustable current source at 50 Hz mains frequency with a current transformer on its output. The internal impedance must be sufficiently high to eliminate the methodic error due to calibration. Calibration is carried out by means of a measuring system controlled by a PC through an IEEE 488 bus. Known values of the simulated ratio error and phase displacement are compared with the values measured by the device that is being tested. A software tool determines the simulated and measured error at each calibration point and determines whether the instrument that is being tested fulfils the parameters stated by the manufacturer.
Název v anglickém jazyce
Use of a Current Source for Calibrating an Automatic Transformer Test Set
Popis výsledku anglicky
This paper describes an innovative procedure for calibrating sets for evaluating instrument current transformer (ICT) errors. The innovation lies in the use of a current source for generating a measured current. There is an adjustable current source at 50 Hz mains frequency with a current transformer on its output. The internal impedance must be sufficiently high to eliminate the methodic error due to calibration. Calibration is carried out by means of a measuring system controlled by a PC through an IEEE 488 bus. Known values of the simulated ratio error and phase displacement are compared with the values measured by the device that is being tested. A software tool determines the simulated and measured error at each calibration point and determines whether the instrument that is being tested fulfils the parameters stated by the manufacturer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16th IMEKO TC4 International Symposium
ISBN
978-88-903149-3-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
University of Florence, Faculty of Engineering and Faculty of Economics
Místo vydání
Florence
Místo konání akce
Florence
Datum konání akce
22. 9. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—