Dynamic Equivalents in Power System Stability Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F09%3A00163658" target="_blank" >RIV/68407700:21230/09:00163658 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamic Equivalents in Power System Stability Analysis
Popis výsledku v původním jazyce
This paper shows a possible solution to the problem of connecting distributed generations to the existing electrical system. In this paper we have processed an advanced model and tools consisted in formulation of the equivalent system in order to study the dynamic behaviour of the system. The results from steady state conditions and short-circuit calculations are the basic information for the formation of the simplified dynamic equivalent. The paper is concerned with transformation of dynamic behavior of the meshed power system to the cooperation dynamic of two regulated generators working to the equivalent connection. The transformation preserves dominant dynamic features of the original system and the resulting layout enables monitoring of faults representation to the value of its equivalent connection and their impact to the function of regulations and protection equipments.
Název v anglickém jazyce
Dynamic Equivalents in Power System Stability Analysis
Popis výsledku anglicky
This paper shows a possible solution to the problem of connecting distributed generations to the existing electrical system. In this paper we have processed an advanced model and tools consisted in formulation of the equivalent system in order to study the dynamic behaviour of the system. The results from steady state conditions and short-circuit calculations are the basic information for the formation of the simplified dynamic equivalent. The paper is concerned with transformation of dynamic behavior of the meshed power system to the cooperation dynamic of two regulated generators working to the equivalent connection. The transformation preserves dominant dynamic features of the original system and the resulting layout enables monitoring of faults representation to the value of its equivalent connection and their impact to the function of regulations and protection equipments.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electric Power Engineering 2009
ISBN
978-80-248-1947-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
VŠB
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou
Datum konání akce
12. 5. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000271440700080