Analytical Model and Investigation of a Four-Switch Space-Vector Modulated Hybrid Power Filter with Six-Fold Switching Symmetry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F09%3A00163705" target="_blank" >RIV/68407700:21230/09:00163705 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/09:00323606
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analytical Model and Investigation of a Four-Switch Space-Vector Modulated Hybrid Power Filter with Six-Fold Switching Symmetry
Popis výsledku v původním jazyce
Shunt Active Power Filters (APF) are nowadays used for mitigation of harmonic currents from nonlinear loads. Current and voltage harmonics have negative effects on the operation of the electric power system. Thus, great attention is focused on harmonic generation and control. Several standards have introduced limits on current harmonics injected into the power system and on voltage harmonics at the bus-bars of the system. A conventional measure for the compensation of non-sinusoidal currents and/or lagging power factor of a load, is represented by tuned passive filters (PF) connected in parallel to the load. However, their frequency characteristics are unfavorably influenced by a variable grid impedance and here, in reality, the danger of the excitation of resonance exists. However, the variations of the filter parameters occur due to aging, temperature, and other operations conditions.
Název v anglickém jazyce
Analytical Model and Investigation of a Four-Switch Space-Vector Modulated Hybrid Power Filter with Six-Fold Switching Symmetry
Popis výsledku anglicky
Shunt Active Power Filters (APF) are nowadays used for mitigation of harmonic currents from nonlinear loads. Current and voltage harmonics have negative effects on the operation of the electric power system. Thus, great attention is focused on harmonic generation and control. Several standards have introduced limits on current harmonics injected into the power system and on voltage harmonics at the bus-bars of the system. A conventional measure for the compensation of non-sinusoidal currents and/or lagging power factor of a load, is represented by tuned passive filters (PF) connected in parallel to the load. However, their frequency characteristics are unfavorably influenced by a variable grid impedance and here, in reality, the danger of the excitation of resonance exists. However, the variations of the filter parameters occur due to aging, temperature, and other operations conditions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA200760703" target="_blank" >IAA200760703: Metody optimalizace umístění a řídicí strategie prvků flexibilních střídavých přenosových systémů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Renewable Energies and Power Quality
ISBN
978-84-612-8014-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Universidad Politécnica de Valencia
Místo vydání
Valencia
Místo konání akce
Valencia
Datum konání akce
15. 4. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—