Experimental FSK Receiver
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F09%3A00179522" target="_blank" >RIV/68407700:21230/09:00179522 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental FSK Receiver
Popis výsledku v původním jazyce
The experimental radio receiver of digitally modulated carrier (frequency shift keying, FSK) has been designed and constructed mainly to measure the detected sequences bit error rate (BER) dependency on the "integrate-and-dump" like demodulator samplingclock timing. The effect of sampling clock timing, sampling clock jitter, signal-to-noise ratio (SNR), and band-pass/low-pass filter transfer characteristic on the BER was evaluated. Based on the results, the receiver sensitivity to precise clock timingwas determined and the demands on the synchronization circuits were specified. The receiver is able to work with modulated signal bandwidth up to 120 kHz with adequate bit rate, however, the band-pass/low-pass filters are changeable to match desired modulating scheme. The radio receiver (after some modifications) partially supports a conference paper (indexed in Thomson ISI) focused on the measurements of the simultaneous angle and amplitude carrier modulation.
Název v anglickém jazyce
Experimental FSK Receiver
Popis výsledku anglicky
The experimental radio receiver of digitally modulated carrier (frequency shift keying, FSK) has been designed and constructed mainly to measure the detected sequences bit error rate (BER) dependency on the "integrate-and-dump" like demodulator samplingclock timing. The effect of sampling clock timing, sampling clock jitter, signal-to-noise ratio (SNR), and band-pass/low-pass filter transfer characteristic on the BER was evaluated. Based on the results, the receiver sensitivity to precise clock timingwas determined and the demands on the synchronization circuits were specified. The receiver is able to work with modulated signal bandwidth up to 120 kHz with adequate bit rate, however, the band-pass/low-pass filters are changeable to match desired modulating scheme. The radio receiver (after some modifications) partially supports a conference paper (indexed in Thomson ISI) focused on the measurements of the simultaneous angle and amplitude carrier modulation.
Klasifikace
Druh
G<sub>funk</sub> - Funkční vzorek
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Interní identifikační kód produktu
ma-er2009
Číselná identifikace
—
Technické parametry
Frequency: 10,7 MHz, bandwidth max.: 120 kHz, sensitivity: < 30 uV. Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.
Ekonomické parametry
Nejsou určeny
Kategorie aplik. výsledku dle nákladů
—
IČO vlastníka výsledku
68407700
Název vlastníka
České vysoké učení technické v Praze
Stát vlastníka
CZ - Česká republika
Druh možnosti využití
N - Využití výsledku jiným subjektem je možné bez nabytí licence (výsledek není licencován)
Požadavek na licenční poplatek
—
Adresa www stránky s výsledkem
—