Arrangement of the Experimental Setup for Determination of Average Kinetic Energy of Reacting Deuterons in Fusion Z-pinch Experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F10%3A00166048" target="_blank" >RIV/68407700:21230/10:00166048 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Arrangement of the Experimental Setup for Determination of Average Kinetic Energy of Reacting Deuterons in Fusion Z-pinch Experiments
Popis výsledku v původním jazyce
The kinetic energy of reacting deuterons is one of the important parameter of the fusion plasma where deuterium is presented in a load. The energy of deuterons is determined from the reconstructed neutron energy spectra which are obtained by extended time-of-flight (TOF) method where time-resolved neutron detectors are placed at several distances on two opposite directions from the neutron source. Provided that the deuteron energy is much smaller than the fusion Q-value, it is possible to show that theneutron energy is only a function of the component of the deuteron kinetic energy (and vice versa) in the direction of neutron detection. Consequently, the side-on and end-on energy components of deuterons can be found on the basis of TOF measurement ofneutrons in the radial and axial directions. Finally, the average kinetic energy of reacting deuterons can be evaluated on an assumption of radial symmetry of neutron production from Z-pinch plasma.
Název v anglickém jazyce
Arrangement of the Experimental Setup for Determination of Average Kinetic Energy of Reacting Deuterons in Fusion Z-pinch Experiments
Popis výsledku anglicky
The kinetic energy of reacting deuterons is one of the important parameter of the fusion plasma where deuterium is presented in a load. The energy of deuterons is determined from the reconstructed neutron energy spectra which are obtained by extended time-of-flight (TOF) method where time-resolved neutron detectors are placed at several distances on two opposite directions from the neutron source. Provided that the deuteron energy is much smaller than the fusion Q-value, it is possible to show that theneutron energy is only a function of the component of the deuteron kinetic energy (and vice versa) in the direction of neutron detection. Consequently, the side-on and end-on energy components of deuterons can be found on the basis of TOF measurement ofneutrons in the radial and axial directions. Finally, the average kinetic energy of reacting deuterons can be evaluated on an assumption of radial symmetry of neutron production from Z-pinch plasma.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Workshop 2010
ISBN
978-80-01-04513-8
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
22. 2. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—