Limitations in Measurement of Leaky Waves on Open Planar Transmission Lines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F10%3A00167984" target="_blank" >RIV/68407700:21230/10:00167984 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Limitations in Measurement of Leaky Waves on Open Planar Transmission Lines
Popis výsledku v původním jazyce
This paper documents leakage on a slotline through simulations done in the CST Microwave Studio. Paper shows the difference between fields of infinite dimensions and finite dimensions of the slotline and then the results of measurement of the electric field. The slotline is designed to radiate power into its substrate in the form of leaky waves in a defined frequency range. The field distribution on a fabricated slotline of finite dimensions was measured in the same way as in the case of the microstripline that was successfully measured in our previous work. The electric field measured above the slotline substrate with the aim of experimental verification of leaky waves is figured out using 3D visualization here. The main aim of the paper is to show that measurement over the substrate is not in general a proper way to verify leaky modes in all types of open planar transmission lines.
Název v anglickém jazyce
Limitations in Measurement of Leaky Waves on Open Planar Transmission Lines
Popis výsledku anglicky
This paper documents leakage on a slotline through simulations done in the CST Microwave Studio. Paper shows the difference between fields of infinite dimensions and finite dimensions of the slotline and then the results of measurement of the electric field. The slotline is designed to radiate power into its substrate in the form of leaky waves in a defined frequency range. The field distribution on a fabricated slotline of finite dimensions was measured in the same way as in the case of the microstripline that was successfully measured in our previous work. The electric field measured above the slotline substrate with the aim of experimental verification of leaky waves is figured out using 3D visualization here. The main aim of the paper is to show that measurement over the substrate is not in general a proper way to verify leaky modes in all types of open planar transmission lines.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 15th Conference on Microwave Techniques COMITE 2010
ISBN
978-1-4244-6351-0
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
VUT v Brně, FEKT, Ústav radioelektroniky
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
19. 4. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—