Popis výsledku v původním jazyce
Automatic measurement facility was implemented at the department of telecommunication of faculty of electrical engineering of Czech technical university in Prague. Measurement facility contains RW switches allowing measurements up to 300MHz or up to 1GHz. Measured twisted pair's parameters can be obtained by measuring but for purposes of fundamental characteristics model is useful to define functions that model the properties of the twisted pair. Its primary and secondary parameters depend mostly on thefrequency. For twisted pair deployment, we are interested in a frequency band range from 1MHz to 100MHz. Measurement methods are commonly implemented in the measuring devices (such as LANTEK) but only for comparison with limit values of twisted pair. The goal of this paper is to optimise a methodology of measuring for the most accurate modelling.
Název v anglickém jazyce
Different Methods for Measurement and Modelling of Twisted Pair Parameters
Popis výsledku anglicky
Automatic measurement facility was implemented at the department of telecommunication of faculty of electrical engineering of Czech technical university in Prague. Measurement facility contains RW switches allowing measurements up to 300MHz or up to 1GHz. Measured twisted pair's parameters can be obtained by measuring but for purposes of fundamental characteristics model is useful to define functions that model the properties of the twisted pair. Its primary and secondary parameters depend mostly on thefrequency. For twisted pair deployment, we are interested in a frequency band range from 1MHz to 100MHz. Measurement methods are commonly implemented in the measuring devices (such as LANTEK) but only for comparison with limit values of twisted pair. The goal of this paper is to optimise a methodology of measuring for the most accurate modelling.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RTT 2010 Proceedings
ISBN
978-80-248-2261-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
VŠB - TUO, FEI, Katedra elektroniky a telekomunikační techniky
Místo vydání
Ostrava
Místo konání akce
Velké Losiny
Datum konání akce
8. 9. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—