The usage of synchrophasor for optimised fault localization method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F10%3A00175777" target="_blank" >RIV/68407700:21230/10:00175777 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The usage of synchrophasor for optimised fault localization method
Popis výsledku v původním jazyce
Common methods for fault localization require for proper function a lot of specialized instruments. These special instruments should be permanently installed or moved to required distribution area. New fault location method needs only a few synchronouslymeasured voltage and current phasors in the fault time for its proper function. The OHL parameters are used for more accurate calculation. The fault is located very quickly using relatively small amount of explained input data and a very special methods. This method can be performed on-line without the line to be switched off. The solving algorithm is based on matrix multiplication with discrete optimization. This is due to the fact that each line segment can be described as the matrix with OHL parameters. During the calculation the immediate fault rate is traced. The evaluation time strongly depends on the computer calculation capabilities and required accuracy.
Název v anglickém jazyce
The usage of synchrophasor for optimised fault localization method
Popis výsledku anglicky
Common methods for fault localization require for proper function a lot of specialized instruments. These special instruments should be permanently installed or moved to required distribution area. New fault location method needs only a few synchronouslymeasured voltage and current phasors in the fault time for its proper function. The OHL parameters are used for more accurate calculation. The fault is located very quickly using relatively small amount of explained input data and a very special methods. This method can be performed on-line without the line to be switched off. The solving algorithm is based on matrix multiplication with discrete optimization. This is due to the fact that each line segment can be described as the matrix with OHL parameters. During the calculation the immediate fault rate is traced. The evaluation time strongly depends on the computer calculation capabilities and required accuracy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník konference ELEN 2010
ISBN
978-80-254-8089-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
ČVUT FEL, Katedra elektroenergetiky
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
20. 9. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—