Large power system disturbances and their consequences represent a challenging problem for the power industry and especially for system operators who are responsible for the network operation, its security and reliability. This fact has reinforced interest in the new generation of monitoring systems with the aim to gain a precise and maximum knowledge about those disturbances and their impact. Most of these severe events with impact on the entire system typically occur in or near the transmission system(TS) and are therefore best monitored at TS level. This puts great demands on the equipments and in general restricts the use of the data since it becomes property of the TSO. Synchronized Phasor Measurement System has emerged as a powerful tool to improve power systems performance and reliability and fault localization possibility. An example of fault event that occurred in TS and was registered by Phasor Measurement Units installed in the distribution system will be shown.
Název v anglickém jazyce
Phasor Measurement Units in Power System Monitoring
Popis výsledku anglicky
Large power system disturbances and their consequences represent a challenging problem for the power industry and especially for system operators who are responsible for the network operation, its security and reliability. This fact has reinforced interest in the new generation of monitoring systems with the aim to gain a precise and maximum knowledge about those disturbances and their impact. Most of these severe events with impact on the entire system typically occur in or near the transmission system(TS) and are therefore best monitored at TS level. This puts great demands on the equipments and in general restricts the use of the data since it becomes property of the TSO. Synchronized Phasor Measurement System has emerged as a powerful tool to improve power systems performance and reliability and fault localization possibility. An example of fault event that occurred in TS and was registered by Phasor Measurement Units installed in the distribution system will be shown.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník konference ELEN 2010
ISBN
978-80-254-8089-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
ČVUT FEL, Katedra elektroenergetiky
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
20. 9. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—