Novel S-Transform Information Fusion for Filtering Ultrasonic Pulse-Echo Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F11%3A00170095" target="_blank" >RIV/68407700:21230/11:00170095 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel S-Transform Information Fusion for Filtering Ultrasonic Pulse-Echo Signals
Popis výsledku v původním jazyce
Direct evaluation of ultrasonic signals requires data analyses with an acceptable level of noise. Ultrasonic signals represent a specific category of time domain signals to be analyzed. In order to increase a difference between the level of noise and theamplitude of the ultrasonic pulse a suitable method for signal filtering has to be used. Within this article we discuss and evaluate a novel signal denoising method. The S-transform for signal analysis and processing was used. This transformation has been recently introduced for ultrasonic echo analyses. Proposed transformation represents an intermediate stage between the Fourier transform analysis and the wavelet transform analysis. In order to filter ultrasonic signals from the Electromagnetic Acoustic Transducer (EMAT) with a high level of noise, new, different approach in signal filtering was developed based on an information fusion. Suggested method is able to process the pulse-echo signal in its full complexity.
Název v anglickém jazyce
Novel S-Transform Information Fusion for Filtering Ultrasonic Pulse-Echo Signals
Popis výsledku anglicky
Direct evaluation of ultrasonic signals requires data analyses with an acceptable level of noise. Ultrasonic signals represent a specific category of time domain signals to be analyzed. In order to increase a difference between the level of noise and theamplitude of the ultrasonic pulse a suitable method for signal filtering has to be used. Within this article we discuss and evaluate a novel signal denoising method. The S-transform for signal analysis and processing was used. This transformation has been recently introduced for ultrasonic echo analyses. Proposed transformation represents an intermediate stage between the Fourier transform analysis and the wavelet transform analysis. In order to filter ultrasonic signals from the Electromagnetic Acoustic Transducer (EMAT) with a high level of noise, new, different approach in signal filtering was developed based on an information fusion. Suggested method is able to process the pulse-echo signal in its full complexity.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BD - Teorie informace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F09%2FH082" target="_blank" >GD102/09/H082: Senzory a inteligentní senzorové systémy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Przeglad Elektrotechniczny
ISSN
0033-2097
e-ISSN
—
Svazek periodika
87
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
290-295
Kód UT WoS článku
000286068300058
EID výsledku v databázi Scopus
—