As the demand for electricity increases, there is a need to increase electricity generation, transmission, and distribution capacities to match the demand. While the location and construction of generation facility is relatively easy, it is becoming increasingly difficult to construct new lines. As a result, electric power authorities everywhere are searching for new ways to maximize the current-carrying capacity of power lines. The paper is divided into two parts: The first part introduces a general review of the parameters that have influence in the determination of the current-carrying capacity, to find a mathematical model to measure the ampacity of the overhead lines and the conductor temperature and analyze all the sensitivities with the main variables. Secondly, an electronic measurement device is proposed and some technical specifications for conductor ampacity and temperature data transfer and evaluation are introduced.
Název v anglickém jazyce
Online Powerline Ampacity Measurement
Popis výsledku anglicky
As the demand for electricity increases, there is a need to increase electricity generation, transmission, and distribution capacities to match the demand. While the location and construction of generation facility is relatively easy, it is becoming increasingly difficult to construct new lines. As a result, electric power authorities everywhere are searching for new ways to maximize the current-carrying capacity of power lines. The paper is divided into two parts: The first part introduces a general review of the parameters that have influence in the determination of the current-carrying capacity, to find a mathematical model to measure the ampacity of the overhead lines and the conductor temperature and analyze all the sensitivities with the main variables. Secondly, an electronic measurement device is proposed and some technical specifications for conductor ampacity and temperature data transfer and evaluation are introduced.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 12th International Scientific Conference Electric Power Engineering 2011
ISBN
978-80-248-2393-5
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
1-3
Název nakladatele
Vysoká škola báňská - Technická univerzita Ostrava
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou
Datum konání akce
17. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—