EXPERIMENTAL STUDY OF CORONA DISCHARGE IN WIREPLATE ELECTROSTATIC PRECIPITATORS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F11%3A00186471" target="_blank" >RIV/68407700:21230/11:00186471 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EXPERIMENTAL STUDY OF CORONA DISCHARGE IN WIREPLATE ELECTROSTATIC PRECIPITATORS
Popis výsledku v původním jazyce
The electrostatic precipitator widely used in the power plants is the highly-efficient dust collection facility. Parallel wire-plate electrode arrangements are widely used to generate corona discharges in various electrostatic processes. The performanceof precipitators can be determined by the current-voltage characteristics. In this work, a laboratory-scale model for prediction of the current-voltage characteristic is presented and experimentally validated for round discharge electrodes in combinationwith plate type collecting electrodes. The model predicts the effect of electrode configuration such as wire diameter, spacing between wire electrodes, number of discharge wires and distance between collecting plates on characteristics of the corona discharge generated in wire-duct precipitator.
Název v anglickém jazyce
EXPERIMENTAL STUDY OF CORONA DISCHARGE IN WIREPLATE ELECTROSTATIC PRECIPITATORS
Popis výsledku anglicky
The electrostatic precipitator widely used in the power plants is the highly-efficient dust collection facility. Parallel wire-plate electrode arrangements are widely used to generate corona discharges in various electrostatic processes. The performanceof precipitators can be determined by the current-voltage characteristics. In this work, a laboratory-scale model for prediction of the current-voltage characteristic is presented and experimentally validated for round discharge electrodes in combinationwith plate type collecting electrodes. The model predicts the effect of electrode configuration such as wire diameter, spacing between wire electrodes, number of discharge wires and distance between collecting plates on characteristics of the corona discharge generated in wire-duct precipitator.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th International Symposium on High Voltage Engineering
ISBN
978-3-8007-3364-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
VDE VERLAG GMBH Berlin
Místo vydání
Berlin
Místo konání akce
Hannover
Datum konání akce
22. 8. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—