Transmission Overhead Lines Audible Noise of Typical EHV Line Configurations Operated in the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F11%3A00188701" target="_blank" >RIV/68407700:21230/11:00188701 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Transmission Overhead Lines Audible Noise of Typical EHV Line Configurations Operated in the Czech Republic
Popis výsledku v původním jazyce
The paper shows calculated and analysed audible noise levels generated by overhead lines of different configurations utilized in the Czech Republic. The surface electrical gradient influencing the line audible noise of conductor wires can be checked by operational voltage and construction parameters, i.e. conductor wires diameter, their surface roughness, conductor wires number in the bundle, symmetrical and nonsymmetrical bundle configuration, phase-to-phase distances in the 3-phase system, phase rotating on the tower, phase conductors height above the ground, mutual distance of parallel 3-phase systems on a double powerline common tower, or separate parallel powerlines distance. The analyses result in important knowledge for configuration design, operation and also for the overhead line trace choice.
Název v anglickém jazyce
Transmission Overhead Lines Audible Noise of Typical EHV Line Configurations Operated in the Czech Republic
Popis výsledku anglicky
The paper shows calculated and analysed audible noise levels generated by overhead lines of different configurations utilized in the Czech Republic. The surface electrical gradient influencing the line audible noise of conductor wires can be checked by operational voltage and construction parameters, i.e. conductor wires diameter, their surface roughness, conductor wires number in the bundle, symmetrical and nonsymmetrical bundle configuration, phase-to-phase distances in the 3-phase system, phase rotating on the tower, phase conductors height above the ground, mutual distance of parallel 3-phase systems on a double powerline common tower, or separate parallel powerlines distance. The analyses result in important knowledge for configuration design, operation and also for the overhead line trace choice.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů