DAC Testing Using Impulse Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00192546" target="_blank" >RIV/68407700:21230/12:00192546 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.metrology.pg.gda.pl/" target="_blank" >http://www.metrology.pg.gda.pl/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/v10178-012-0009-8" target="_blank" >10.2478/v10178-012-0009-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DAC Testing Using Impulse Signals
Popis výsledku v původním jazyce
The Multi-Tone (MT) signal with uniform amplitudes can be used for DAC testing. This paper shows an easier way to generate a MT signal using several impulse signals. The article also analyzes qualities of methods for testing the dynamic parameters of Digital to Analog Converters using an impulse signal. The MT, Damped Sine Wave (DSW) and Sinx/x (SINC) signals will be used as the source for these tests. The Effective Number of Bits (ENOB) and Signal to noise and distortion (SINAD) are evaluated in the frequency domain and they are modified using the Crest Factor (CF) correction and compared with the standard results of the Sine Wave FFT test. The first advantage of the test using an impulse signal is that you need fewer input parameters to create the band signal for testing the DAC. The second one is to reduce the testing time using a band signal in comparison with multiple tests using a single sine wave.
Název v anglickém jazyce
DAC Testing Using Impulse Signals
Popis výsledku anglicky
The Multi-Tone (MT) signal with uniform amplitudes can be used for DAC testing. This paper shows an easier way to generate a MT signal using several impulse signals. The article also analyzes qualities of methods for testing the dynamic parameters of Digital to Analog Converters using an impulse signal. The MT, Damped Sine Wave (DSW) and Sinx/x (SINC) signals will be used as the source for these tests. The Effective Number of Bits (ENOB) and Signal to noise and distortion (SINAD) are evaluated in the frequency domain and they are modified using the Crest Factor (CF) correction and compared with the standard results of the Sine Wave FFT test. The first advantage of the test using an impulse signal is that you need fewer input parameters to create the band signal for testing the DAC. The second one is to reduce the testing time using a band signal in comparison with multiple tests using a single sine wave.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrology and Measurement Systems
ISSN
0860-8229
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
10
Strana od-do
105-114
Kód UT WoS článku
000302125500009