Using Nonlinear Features for Fetal Heart Rate Classification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00193060" target="_blank" >RIV/68407700:21230/12:00193060 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/65269705:_____/12:#0001674 RIV/00064165:_____/12:13565
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1746809411000619" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1746809411000619</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bspc.2011.06.008" target="_blank" >10.1016/j.bspc.2011.06.008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using Nonlinear Features for Fetal Heart Rate Classification
Popis výsledku v původním jazyce
Fetal heart rate (FHR) is used to evaluate fetal well-being and enables clinicians to detect ongoing hypoxia during delivery. Routine clinical evaluation of intrapartum FHR is based on macroscopic morphological features visible to the naked eye. In thispaper we evaluated conventional features and compared them to the nonlinear ones in the task of intrapartum FHR classification. The experiments were performed using a database of 217 FHR records with objective annotations, i.e. pH measurement. We have proven that the addition of nonlinear features improves accuracy of classification. The best classification results were achieved using a combination of conventional and nonlinear features with sensitivity of 73.4%, specificity of 76.3%, and F-measure of 71.9%. The best selected nonlinear features were: Lempel Ziv complexity, Sample entropy, and fractal dimension estimated by Higuchi method. Since the results of automatic signal evaluation are easily reproducible, the process of FHR evalua
Název v anglickém jazyce
Using Nonlinear Features for Fetal Heart Rate Classification
Popis výsledku anglicky
Fetal heart rate (FHR) is used to evaluate fetal well-being and enables clinicians to detect ongoing hypoxia during delivery. Routine clinical evaluation of intrapartum FHR is based on macroscopic morphological features visible to the naked eye. In thispaper we evaluated conventional features and compared them to the nonlinear ones in the task of intrapartum FHR classification. The experiments were performed using a database of 217 FHR records with objective annotations, i.e. pH measurement. We have proven that the addition of nonlinear features improves accuracy of classification. The best classification results were achieved using a combination of conventional and nonlinear features with sensitivity of 73.4%, specificity of 76.3%, and F-measure of 71.9%. The best selected nonlinear features were: Lempel Ziv complexity, Sample entropy, and fractal dimension estimated by Higuchi method. Since the results of automatic signal evaluation are easily reproducible, the process of FHR evalua
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT11124" target="_blank" >NT11124: Vliv hodnocení kardiotokografie pomocí metod umělé inteligence na kvalitu perinatální péče</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Signal Processing and Control
ISSN
1746-8094
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
350-357
Kód UT WoS článku
000304843400005
EID výsledku v databázi Scopus
—