Comparison of Alternative Equivalent Circuits of Induc-tion Motor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00193275" target="_blank" >RIV/68407700:21230/12:00193275 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/12:00193275
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Alternative Equivalent Circuits of Induc-tion Motor
Popis výsledku v původním jazyce
Nowadays in variable speed drives induction machines are widely used. For the understanding and clear specifica-tion of the electromagnetic processes in the induction ma-chines different equivalent circuits can be employed. Traditionally, in order to reduce the complexity of the mathematical model the resistances and inductances are represented as concentrated components and 3 phase wind-ing is assumed to be symmetrical. These equivalent circuits are also used as a starting point for the design of the drive controller. This article strives to compare the two most widely used models and to derive a transformation against each other. In most papers that deal with the problematic of the IM drive control, equation based on the Park's transformation as a T-formed equivalent circuit are used. These models are adequate in many situations. Even though they can seem to be overly simplified, they can serve as a solid basis for an advanced motor control. However other authors tend to use gamma mo
Název v anglickém jazyce
Comparison of Alternative Equivalent Circuits of Induc-tion Motor
Popis výsledku anglicky
Nowadays in variable speed drives induction machines are widely used. For the understanding and clear specifica-tion of the electromagnetic processes in the induction ma-chines different equivalent circuits can be employed. Traditionally, in order to reduce the complexity of the mathematical model the resistances and inductances are represented as concentrated components and 3 phase wind-ing is assumed to be symmetrical. These equivalent circuits are also used as a starting point for the design of the drive controller. This article strives to compare the two most widely used models and to derive a transformation against each other. In most papers that deal with the problematic of the IM drive control, equation based on the Park's transformation as a T-formed equivalent circuit are used. These models are adequate in many situations. Even though they can seem to be overly simplified, they can serve as a solid basis for an advanced motor control. However other authors tend to use gamma mo
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 13th International Scientific Conference EPE 2012
ISBN
978-80-214-4514-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1081-1086
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
23. 5. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—