The Acoustic Resonator Combined with Electrical Discharges
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00198958" target="_blank" >RIV/68407700:21230/12:00198958 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=6269152" target="_blank" >http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=6269152</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ULTSYM.2011.0128" target="_blank" >10.1109/ULTSYM.2011.0128</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Acoustic Resonator Combined with Electrical Discharges
Popis výsledku v původním jazyce
The important factors in industrial applications are discharge power and volume. In order to increase those and to prevent a discharge transition into sparks, we designed a discharge stabilization of multi-needle to axial-wire electrode system, which issituated in the pressure node of the acoustic resonator. The discharge streamers are strongly spread. The discharges are stabilized at all needles even if they are connected to the same potential. The needle tips are effectively cooled by the acoustic wave. Several multi-needle electrodes can be placed around the resonator diameter centered at the node plane so that the considerable resonator node volume is filled with the discharges. The stabilization may be applied to different regimes of discharges;e.g. corona, glow and streamer.
Název v anglickém jazyce
The Acoustic Resonator Combined with Electrical Discharges
Popis výsledku anglicky
The important factors in industrial applications are discharge power and volume. In order to increase those and to prevent a discharge transition into sparks, we designed a discharge stabilization of multi-needle to axial-wire electrode system, which issituated in the pressure node of the acoustic resonator. The discharge streamers are strongly spread. The discharges are stabilized at all needles even if they are connected to the same potential. The needle tips are effectively cooled by the acoustic wave. Several multi-needle electrodes can be placed around the resonator diameter centered at the node plane so that the considerable resonator node volume is filled with the discharges. The stabilization may be applied to different regimes of discharges;e.g. corona, glow and streamer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2011 IEEE International Ultrasonics Symposium (IUS)
ISBN
978-1-4577-1252-4
ISSN
1948-5719
e-ISSN
—
Počet stran výsledku
4
Strana od-do
531-534
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Orlando
Datum konání akce
18. 10. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce