This paper deals with voltage regulation at a distribution level. Based on the boom of renewable generation in Czech Republic or generally in the Europe there were appeared an issue with an inappropriate voltage regulation of this dispersed generation. Several approaches were adopted by distribution system operators from least common constant reactive power delivery to more frequent constant power factor or constant voltage regulation at a point of connection. The work of this paper has been related toadoption of an adaptive control scheme for a photovoltaic power plant, which is connected via inverter to the grid to provide a reactive power delivery or absorption, to achieve appropriate settings of PI control parameters, which lead to better voltagequality. The inverter with pulse-width modulation has been used in this study. The formulation of an adaptive method is presented and due to the fact that nowadays all PI regulators are digital, the voltage regulator is modelled in discre
Název v anglickém jazyce
Effects of Adaptive Voltage Control on Distribution Grid
Popis výsledku anglicky
This paper deals with voltage regulation at a distribution level. Based on the boom of renewable generation in Czech Republic or generally in the Europe there were appeared an issue with an inappropriate voltage regulation of this dispersed generation. Several approaches were adopted by distribution system operators from least common constant reactive power delivery to more frequent constant power factor or constant voltage regulation at a point of connection. The work of this paper has been related toadoption of an adaptive control scheme for a photovoltaic power plant, which is connected via inverter to the grid to provide a reactive power delivery or absorption, to achieve appropriate settings of PI control parameters, which lead to better voltagequality. The inverter with pulse-width modulation has been used in this study. The formulation of an adaptive method is presented and due to the fact that nowadays all PI regulators are digital, the voltage regulator is modelled in discre
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ELEN 2012
ISBN
978-80-01-05096-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
vydavatelství ČVUT v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
11. 9. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—