Methodology for Lightning Protection of Medium and High Voltage Networks
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00200091" target="_blank" >RIV/68407700:21230/12:00200091 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methodology for Lightning Protection of Medium and High Voltage Networks
Popis výsledku v původním jazyce
This paper critically analyses different theoretical methods of medium (MV) and high (HV) voltage networks in order to prevent damages caused by lightning. Medium voltage networks distances suggested by international standards and recommendations (CIGRE,IEEE, etc) are critically scrutinized. Shielding protection techniques in high voltage networks are risk assessed emphasizing successful examples of uses in the Argentinean network & power generation market. The MV approach is assessed by means of a critical ex-post analysis of the work performed in the City Bell MV grid in order to evaluate the maximum admissible distance between arresters and transformers including transformer voltage (Ua) and maximum distance (L). Calculations are detailed, as wellas, usual configuration levels to establish the practical links between lightning arresters and protected appliances. The HV approach is considered by means of two critical studies: an existing 132 kV power line with triangular dispositio
Název v anglickém jazyce
Methodology for Lightning Protection of Medium and High Voltage Networks
Popis výsledku anglicky
This paper critically analyses different theoretical methods of medium (MV) and high (HV) voltage networks in order to prevent damages caused by lightning. Medium voltage networks distances suggested by international standards and recommendations (CIGRE,IEEE, etc) are critically scrutinized. Shielding protection techniques in high voltage networks are risk assessed emphasizing successful examples of uses in the Argentinean network & power generation market. The MV approach is assessed by means of a critical ex-post analysis of the work performed in the City Bell MV grid in order to evaluate the maximum admissible distance between arresters and transformers including transformer voltage (Ua) and maximum distance (L). Calculations are detailed, as wellas, usual configuration levels to establish the practical links between lightning arresters and protected appliances. The HV approach is considered by means of two critical studies: an existing 132 kV power line with triangular dispositio
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ELEN 2012
ISBN
978-80-01-05096-5
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
1-10
Název nakladatele
vydavatelství ČVUT v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
11. 9. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—