Selecting network parameters to achieve optimal power flow with minimal active power losses is very important for utility companies from economical point of view, on other side there is necessity of maintaining the network in the safe distance from voltage collapse. This paper discusses general problem of minimization of power network losses and classification of variables and parameters for power system safety operation assessment. The article's main goal is to study local safety in specific node and evaluate its correlation to active power losses. Safety factor, used in the article, is proportionate to the smallest distance of working point [R, Q, U] of a node from the set of critical points, which is determined on the basis of the Tevenine model. Overall stability factor (based on all single node factors) is calculated for all network setups (transformer taps and generator output voltages) and it is determined whether the most optimal setup is safe enough or if there is safer soluti
Název v anglickém jazyce
Power Network Losses Minimization in Correlation with Voltage Security
Popis výsledku anglicky
Selecting network parameters to achieve optimal power flow with minimal active power losses is very important for utility companies from economical point of view, on other side there is necessity of maintaining the network in the safe distance from voltage collapse. This paper discusses general problem of minimization of power network losses and classification of variables and parameters for power system safety operation assessment. The article's main goal is to study local safety in specific node and evaluate its correlation to active power losses. Safety factor, used in the article, is proportionate to the smallest distance of working point [R, Q, U] of a node from the set of critical points, which is determined on the basis of the Tevenine model. Overall stability factor (based on all single node factors) is calculated for all network setups (transformer taps and generator output voltages) and it is determined whether the most optimal setup is safe enough or if there is safer soluti
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ELEN 2012
ISBN
978-80-01-05096-5
ISSN
—
e-ISSN
—
Počet stran výsledku
16
Strana od-do
1-16
Název nakladatele
vydavatelství ČVUT v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
11. 9. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—