Advanced Applications of FACTS in Industrial Distribution Systems in Middle Europe
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00200099" target="_blank" >RIV/68407700:21230/12:00200099 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advanced Applications of FACTS in Industrial Distribution Systems in Middle Europe
Popis výsledku v původním jazyce
The paper deals with the possibilities of FACTS devices installation and operation in the Middle European distribution systems. A voltage fluctuation that results in flicker is caused by Electrical Arc Furnace (EAF) power fluctuation. The UPQC can be aneffective means to suppress voltage fluctuation connected with the function of the EAF. Hitherto, the flicker has been compensated for mainly by using Static Var Compensators (SVC), whose capability to eliminate voltage subharmonics is limited by the frequency up to 10 Hz at maximum. A model of a power system with an electric arc furnace was developed for a typical metallurgical plant. The paper would like to emphasize that FACTS devices should have their position not only in large transmission system but for specific tasks also in local distribution systems. This is all connected with technical-economical decision how to approach to solving all partial electrical systems operational issues.
Název v anglickém jazyce
Advanced Applications of FACTS in Industrial Distribution Systems in Middle Europe
Popis výsledku anglicky
The paper deals with the possibilities of FACTS devices installation and operation in the Middle European distribution systems. A voltage fluctuation that results in flicker is caused by Electrical Arc Furnace (EAF) power fluctuation. The UPQC can be aneffective means to suppress voltage fluctuation connected with the function of the EAF. Hitherto, the flicker has been compensated for mainly by using Static Var Compensators (SVC), whose capability to eliminate voltage subharmonics is limited by the frequency up to 10 Hz at maximum. A model of a power system with an electric arc furnace was developed for a typical metallurgical plant. The paper would like to emphasize that FACTS devices should have their position not only in large transmission system but for specific tasks also in local distribution systems. This is all connected with technical-economical decision how to approach to solving all partial electrical systems operational issues.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů