This paper presents a predictive controller based on the thermal model of a hotel located on a tropical island. The guestrooms of the selected hotel are classified according to their dimension, neighboring rooms, and the influence of the solar radiationon the roof and external walls, and are modeled in TRNSYS, a well-known software for simulating heat transfer processes in buildings. In this simulation environment, the thermal load of the resulting guestroom module is calculated as a function of the comfort set point temperature, the ambient temperature, and the solar radiation for the situated geographic zone, and the heat gains due to occupancy and equipment presented in the guestrooms. Based on the analogy between resistance-capacitance electricalcircuits and heat transfer in buildings, a model for control purposes capturing the thermal dynamics of the guestroom and the above disturbances is proposed, and its parameters are obtained by using grey box identification techniques. Thi
Název v anglickém jazyce
Model Predictive Control for a Tropical Island Hotel
Popis výsledku anglicky
This paper presents a predictive controller based on the thermal model of a hotel located on a tropical island. The guestrooms of the selected hotel are classified according to their dimension, neighboring rooms, and the influence of the solar radiationon the roof and external walls, and are modeled in TRNSYS, a well-known software for simulating heat transfer processes in buildings. In this simulation environment, the thermal load of the resulting guestroom module is calculated as a function of the comfort set point temperature, the ambient temperature, and the solar radiation for the situated geographic zone, and the heat gains due to occupancy and equipment presented in the guestrooms. Based on the analogy between resistance-capacitance electricalcircuits and heat transfer in buildings, a model for control purposes capturing the thermal dynamics of the guestroom and the above disturbances is proposed, and its parameters are obtained by using grey box identification techniques. Thi
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Clima 2013 - 11th REHVA World Congress & 8th International Conference on IAQVEC - "Energy Efficient, Smart and Healthy Buildings"
ISBN
978-80-260-4001-9
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
5917-5927
Název nakladatele
Společnost pro techniku prostředí
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
16. 6. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—