Popis výsledku v původním jazyce
This paper deals with the losses analysis of electrical power in distribution network transformers. There are two kinds of losses in transformers, the core losses P0 in the magnetic circuit and short-circuit losses Pk in the windings. In the theoreticalpart I analyze the losses location and their causes. In need to ensure continual electricity supply relevance of independent no-load losses is very strong. They are independent on power load. To reduce no-load losses we can change structural and technological measures (core profile shape, direction of sheet rolling, rolling burr, etc.) or use entirely new magnetic materials used in modern magnetic circuits. The designed power amorphous distribution transformers with low losses reach values of 2/3 lowerno-load losses and 1/3 lower total looses at the load factor 0,5.
Název v anglickém jazyce
Design of Series Amorphous Distribution Transformers
Popis výsledku anglicky
This paper deals with the losses analysis of electrical power in distribution network transformers. There are two kinds of losses in transformers, the core losses P0 in the magnetic circuit and short-circuit losses Pk in the windings. In the theoreticalpart I analyze the losses location and their causes. In need to ensure continual electricity supply relevance of independent no-load losses is very strong. They are independent on power load. To reduce no-load losses we can change structural and technological measures (core profile shape, direction of sheet rolling, rolling burr, etc.) or use entirely new magnetic materials used in modern magnetic circuits. The designed power amorphous distribution transformers with low losses reach values of 2/3 lowerno-load losses and 1/3 lower total looses at the load factor 0,5.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů