Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F13%3A00222694" target="_blank" >RIV/68407700:21230/13:00222694 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint
Popis výsledku v původním jazyce
This research evaluated an impact of flexion and extension heel pad on surface electromyography of the muscles (Vastus medialis and Vastus lateralis). For signal processing were used Ambu Blue Sensor P, Biomonitor ME6000 MegaWin and software MegaWin 700046 version 3.0. Nineteen healthy subjects of both genders (15 women ? 23.5?4.0 years, 4 men ? 32.8?11.8 years) volunteered to participate in the study. 19 parameters for evaluation were selected and calculated in MATLAB and statistical evaluation was performed in Microsoft Excel 2007. The ANOVA method followed by post hoc analysis (Tukey method) was chosen for statistical analysis. There were detected only two parameters where there were statistically significant differences (p <0.05) in muscle activityin measurements without reflex heel pad vs. supine reflex heel pad (parameter Median, absolute value of the differences between means: 1.07 ?V, p = 0.047) and also in measurements without reflex heel pad vs. pronation reflex heel pad (pa
Název v anglickém jazyce
Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint
Popis výsledku anglicky
This research evaluated an impact of flexion and extension heel pad on surface electromyography of the muscles (Vastus medialis and Vastus lateralis). For signal processing were used Ambu Blue Sensor P, Biomonitor ME6000 MegaWin and software MegaWin 700046 version 3.0. Nineteen healthy subjects of both genders (15 women ? 23.5?4.0 years, 4 men ? 32.8?11.8 years) volunteered to participate in the study. 19 parameters for evaluation were selected and calculated in MATLAB and statistical evaluation was performed in Microsoft Excel 2007. The ANOVA method followed by post hoc analysis (Tukey method) was chosen for statistical analysis. There were detected only two parameters where there were statistically significant differences (p <0.05) in muscle activityin measurements without reflex heel pad vs. supine reflex heel pad (parameter Median, absolute value of the differences between means: 1.07 ?V, p = 0.047) and also in measurements without reflex heel pad vs. pronation reflex heel pad (pa
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
BioDat 2013 - Conference on Advanced Methods of Biological Data and Signal Processing
ISBN
978-80-01-05410-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
21. 11. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—