Detection of Artifacts in Oscillometric Pulsations Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00219419" target="_blank" >RIV/68407700:21230/14:00219419 - isvavai.cz</a>
Výsledek na webu
<a href="http://emb.citengine.com/event/bhi-2014/details" target="_blank" >http://emb.citengine.com/event/bhi-2014/details</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/BHI.2014.6864462" target="_blank" >10.1109/BHI.2014.6864462</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Artifacts in Oscillometric Pulsations Signals
Popis výsledku v původním jazyce
A measurement of blood pressure is a basic diagnostic technique for examining of the cardiovascular system. There are a lot of methods for determination of the blood pressure, but an oscillometric measurement (investigation of oscillometric pulsations) is one of the most frequent methods used in modern electronic tonometers. The results given by oscillometric measurements are very dependent on the cleanness of the signal. The method is very sensitive for example for motion artifacts, which produce significant damage of the signal. For the proper processing of the signal it is very important to detect all artifacts precisely before signal processing. The paper deals with the methods for artifacts detection in oscillometric pulsations signals. The methods based on predicted heart rate detection, heart rate variability (standard deviation method) and comparison of oscillometric pulsations with ECG signal are described in the paper. The section Results includes a comparison of the methods
Název v anglickém jazyce
Detection of Artifacts in Oscillometric Pulsations Signals
Popis výsledku anglicky
A measurement of blood pressure is a basic diagnostic technique for examining of the cardiovascular system. There are a lot of methods for determination of the blood pressure, but an oscillometric measurement (investigation of oscillometric pulsations) is one of the most frequent methods used in modern electronic tonometers. The results given by oscillometric measurements are very dependent on the cleanness of the signal. The method is very sensitive for example for motion artifacts, which produce significant damage of the signal. For the proper processing of the signal it is very important to detect all artifacts precisely before signal processing. The paper deals with the methods for artifacts detection in oscillometric pulsations signals. The methods based on predicted heart rate detection, heart rate variability (standard deviation method) and comparison of oscillometric pulsations with ECG signal are described in the paper. The section Results includes a comparison of the methods
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Biomedical and Health Informatics
ISBN
978-1-4799-2131-7
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
709-711
Název nakladatele
IEEE Engineering in Medicine and Biology Society
Místo vydání
New Jersey
Místo konání akce
Valencia
Datum konání akce
1. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000346504900170