Clinical evaluation versus automatic detection of interictal epileptiform discharges ? who can we trust?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00223610" target="_blank" >RIV/68407700:21230/14:00223610 - isvavai.cz</a>
Výsledek na webu
<a href="http://csskn2014.upol.cz/site2014/wp-content/uploads/2014/05/abstracts_tematicke_sekce_sjezdu.pdf" target="_blank" >http://csskn2014.upol.cz/site2014/wp-content/uploads/2014/05/abstracts_tematicke_sekce_sjezdu.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Clinical evaluation versus automatic detection of interictal epileptiform discharges ? who can we trust?
Popis výsledku v původním jazyce
Objective. Interictal epileptiform discharges (IEDs) are electrographic hallmark of epilepsy. Information about the spatiotemporal distribution of IEDs in intracranial EEG is utilized to localize epileptogenic zone during the presurgical evaluation and plan the resection. Visual evaluation of long-term multi-channel intracranial recordings is extremely difficult and prone to bias. Clinicians usually assess only high-amplitude (high signal to noise ratio) discharge and low-amplitude IEDs can be overlooked or considered clinically insignificant. The goal of our study was to develop reliable automatic IED detectors to facilitate analysis of long-term recordings and increase the information yield of intracranial recordings. Methods. Seven intracranial EEGrecordings were randomly selected from our database. Samples of five minutes duration from fifteen high-rate IED channels (525 minutes in total) were presented to three experienced EEG specialists for spike labelling. The readers independ
Název v anglickém jazyce
Clinical evaluation versus automatic detection of interictal epileptiform discharges ? who can we trust?
Popis výsledku anglicky
Objective. Interictal epileptiform discharges (IEDs) are electrographic hallmark of epilepsy. Information about the spatiotemporal distribution of IEDs in intracranial EEG is utilized to localize epileptogenic zone during the presurgical evaluation and plan the resection. Visual evaluation of long-term multi-channel intracranial recordings is extremely difficult and prone to bias. Clinicians usually assess only high-amplitude (high signal to noise ratio) discharge and low-amplitude IEDs can be overlooked or considered clinically insignificant. The goal of our study was to develop reliable automatic IED detectors to facilitate analysis of long-term recordings and increase the information yield of intracranial recordings. Methods. Seven intracranial EEGrecordings were randomly selected from our database. Samples of five minutes duration from fifteen high-rate IED channels (525 minutes in total) were presented to three experienced EEG specialists for spike labelling. The readers independ
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů