FACTS Devices Influence on Power Losses in Transmission Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00224515" target="_blank" >RIV/68407700:21230/14:00224515 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EPE.2014.6839431" target="_blank" >http://dx.doi.org/10.1109/EPE.2014.6839431</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2014.6839431" target="_blank" >10.1109/EPE.2014.6839431</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
FACTS Devices Influence on Power Losses in Transmission Systems
Popis výsledku v původním jazyce
Since there are still higher efforts for transmission systems equipment utilization, more control mechanisms and devices are integrated to the systems and their dispatch centers and these will be also in future. FACTS devices purpose is preferably to maintain voltage levels and to control active and reactive power flows. Their implementation in the grid can result from the necessity to improve the system capabilities in a longterm period or to solve some extraordinary states. The paper deals with the implementation of shunt and series FACTS devices into electrical transmission systems and their influence on active power losses. There are provided comparison analyses of how different FACTS types have a potential to changes power losses in the system either in a negative or in a positive way. There are explained basic principles and the results are presented on the IEEE/CIGRE transmission system model.
Název v anglickém jazyce
FACTS Devices Influence on Power Losses in Transmission Systems
Popis výsledku anglicky
Since there are still higher efforts for transmission systems equipment utilization, more control mechanisms and devices are integrated to the systems and their dispatch centers and these will be also in future. FACTS devices purpose is preferably to maintain voltage levels and to control active and reactive power flows. Their implementation in the grid can result from the necessity to improve the system capabilities in a longterm period or to solve some extraordinary states. The paper deals with the implementation of shunt and series FACTS devices into electrical transmission systems and their influence on active power losses. There are provided comparison analyses of how different FACTS types have a potential to changes power losses in the system either in a negative or in a positive way. There are explained basic principles and the results are presented on the IEEE/CIGRE transmission system model.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2014 15th International Scientific Conference on Electric Power Engineering
ISBN
978-1-4799-3807-0
ISSN
—
e-ISSN
2376-5623
Počet stran výsledku
5
Strana od-do
29-33
Název nakladatele
Vysoké učení technické v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000358740100006