Multimode fiber tapers for reproducible refractometric liquid detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00229383" target="_blank" >RIV/68407700:21230/15:00229383 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/1.OE.54.4.047102" target="_blank" >http://dx.doi.org/10.1117/1.OE.54.4.047102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/1.OE.54.4.047102" target="_blank" >10.1117/1.OE.54.4.047102</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multimode fiber tapers for reproducible refractometric liquid detection
Popis výsledku v původním jazyce
This paper describes the refractometric detection of liquids based on silica multimode optical fibers which were tapered to increase the evanescent-wave overlap for higher sensor sensitivity. By precisely monitoring the production process, consistent sample parameters were achieved. More than 200 tapers with a taper waist diameter range from 6.0 to 76.3 μm were prepared from polymer-clad silica and gradient-index multimode fibers. U-shaped fiber taper sensitivities were analytically compared with straight tapers with resulting intensity sensitivities of over 200%/RIU. Crucial parameters for real sensor applications, such as measurement repeatability, reproducibility, and long-term stability, were further studied for polymer-clad silica straight tapers. Longterm stability was monitored showing stable measurement results over a 6 months long interval. Measurement repeatability and reproducibility with standard deviations of 0.55%/RIU and 2.26%/RIU, respectively, were achieved.
Název v anglickém jazyce
Multimode fiber tapers for reproducible refractometric liquid detection
Popis výsledku anglicky
This paper describes the refractometric detection of liquids based on silica multimode optical fibers which were tapered to increase the evanescent-wave overlap for higher sensor sensitivity. By precisely monitoring the production process, consistent sample parameters were achieved. More than 200 tapers with a taper waist diameter range from 6.0 to 76.3 μm were prepared from polymer-clad silica and gradient-index multimode fibers. U-shaped fiber taper sensitivities were analytically compared with straight tapers with resulting intensity sensitivities of over 200%/RIU. Crucial parameters for real sensor applications, such as measurement repeatability, reproducibility, and long-term stability, were further studied for polymer-clad silica straight tapers. Longterm stability was monitored showing stable measurement results over a 6 months long interval. Measurement repeatability and reproducibility with standard deviations of 0.55%/RIU and 2.26%/RIU, respectively, were achieved.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA03010060" target="_blank" >TA03010060: Vláknově optická detekce kapalin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optical Engineering
ISSN
0091-3286
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
"047102-1"-"047102-6"
Kód UT WoS článku
000355207800033
EID výsledku v databázi Scopus
—