DESIGN AND REALIZATION OF MEASURING DEVICE FOR TREMOR EVALUATION
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00233475" target="_blank" >RIV/68407700:21230/15:00233475 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/15:71020 RIV/00216208:11120/15:43911810
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DESIGN AND REALIZATION OF MEASURING DEVICE FOR TREMOR EVALUATION
Popis výsledku v původním jazyce
Tremor as an involuntary rhythmic oscillatory movement of a body part belongs to one of the most disabling features of multiple sclerosis. Our research presented in this paper deals with the developing of an evaluation system of tremor. The system whichwas designed and ealized consists of the portable telemetry units with accelerometers and the base station. The system is able to store 3 axes accelerometry data in the dynamic range of ? 8 g and the sample frequency of 50 Hz. The system allows storing raw data for further processing in PC. The device was verified in the experiment with the gravitational acceleration. The illustration of results from pilot study are presented in the result section. These results show the system ability to trace varioustypes of tremors and distinguish between them.
Název v anglickém jazyce
DESIGN AND REALIZATION OF MEASURING DEVICE FOR TREMOR EVALUATION
Popis výsledku anglicky
Tremor as an involuntary rhythmic oscillatory movement of a body part belongs to one of the most disabling features of multiple sclerosis. Our research presented in this paper deals with the developing of an evaluation system of tremor. The system whichwas designed and ealized consists of the portable telemetry units with accelerometers and the base station. The system is able to store 3 axes accelerometry data in the dynamic range of ? 8 g and the sample frequency of 50 Hz. The system allows storing raw data for further processing in PC. The device was verified in the experiment with the gravitational acceleration. The illustration of results from pilot study are presented in the result section. These results show the system ability to trace varioustypes of tremors and distinguish between them.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
INTERNATIONAL WORKSHOP ON COMPUTATIONAL INTELLIGENCE FOR MULTIMEDIA UNDERSTANDING
ISBN
978-1-4673-8457-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
29. 10. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—