Dynamic behaviour of overhead line under icing conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00235583" target="_blank" >RIV/68407700:21230/15:00235583 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamic behaviour of overhead line under icing conditions
Popis výsledku v původním jazyce
The paper deals with dynamic model of overhead line mechanics. Dynamical modelling are useful to study many different transient states and it is also possible used for determination of an effects of various influences. The analysis thus allows to detectpotentially dangerous situations and can be prevented by performing the corrective actions. In contrast to the static model, dynamic model also allows to simulate the shock forces and determine the peak exceeding the allowable limits of safe state of operation of overhead lines. The mechanical model of the power line is based on modeling each elements and interaction of its neighbors. This method allows the description of complex structures. Each element has mass, length, rigidity and damping. Each model function is modelled as block with internal interaction. In case study is transient state with conductor ACSR 350/59 analyzed. Transient state is induced fall icy.
Název v anglickém jazyce
Dynamic behaviour of overhead line under icing conditions
Popis výsledku anglicky
The paper deals with dynamic model of overhead line mechanics. Dynamical modelling are useful to study many different transient states and it is also possible used for determination of an effects of various influences. The analysis thus allows to detectpotentially dangerous situations and can be prevented by performing the corrective actions. In contrast to the static model, dynamic model also allows to simulate the shock forces and determine the peak exceeding the allowable limits of safe state of operation of overhead lines. The mechanical model of the power line is based on modeling each elements and interaction of its neighbors. This method allows the description of complex structures. Each element has mass, length, rigidity and damping. Each model function is modelled as block with internal interaction. In case study is transient state with conductor ACSR 350/59 analyzed. Transient state is induced fall icy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 8th International Scientific Symposium on Electrical Power Engineering ELEKTROENERGETIKA 2015
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
105-108
Název nakladatele
TU Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000361561700024