New Method for Transformer Winding Fault Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00235624" target="_blank" >RIV/68407700:21230/15:00235624 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New Method for Transformer Winding Fault Detection
Popis výsledku v původním jazyce
This paper contents a description of frequency diagnostic methods for detection of transformer winding condition. This group of considerate offline test methods is very important for a modern power transformer diagnostic. First, principles of often usedmethods the Low Voltage Impulse Method (LVIM) and the Sweep Frequency Response Analysis method (SFRA) are briefly explained and then the new method using a chirp signal is proposed. The test program is programmed in the software MATLAB. Theoretically, the new method using the chirp signal should provide better evaluation and application. The functionality and performance of these methods is verified by realization of real test measurements and the methods applicability compare to chirp signal method isdiscussed at the end.
Název v anglickém jazyce
New Method for Transformer Winding Fault Detection
Popis výsledku anglicky
This paper contents a description of frequency diagnostic methods for detection of transformer winding condition. This group of considerate offline test methods is very important for a modern power transformer diagnostic. First, principles of often usedmethods the Low Voltage Impulse Method (LVIM) and the Sweep Frequency Response Analysis method (SFRA) are briefly explained and then the new method using a chirp signal is proposed. The test program is programmed in the software MATLAB. Theoretically, the new method using the chirp signal should provide better evaluation and application. The functionality and performance of these methods is verified by realization of real test measurements and the methods applicability compare to chirp signal method isdiscussed at the end.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 19th International Scientific Student Conferenece POSTER 2015
ISBN
978-80-01-05499-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Czech Technical University in Prague
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
14. 5. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—