Analysis of Current Unbalance in Meshed Transmission System
Popis výsledku v původním jazyce
The paper describes new approach of the calculation of current unbalance in a meshed transmission system. The system is composed of several parts with different types of towers, phase sequence arrangements, types of conductors and one or two transmission lines on the same tower. The calculations are performed by dividing the problem to a number of impedance matrices respecting the mutual impedances between all conductors. In the examined transmission system there exist parts with different number of lines but the same number of shield wires. For connection of parts with two transmission lines and two shield wires to another part with one transmission line and two shield wires, virtual shield wires must be created to keep the continuity of the calculations. After current unbalance calculations, necessary steps must be taken to symmetrize the part of the transmission system examined. Due to requirement of changing phase sequence arrangement only in one part of our system, classical way of transposition based on line division into three parts and alternation of conductors between themselves cannot be used. All possible phase sequence arrangements in each transmission line of the part of the system are examined, the best solution must be then calculated and selected.
Název v anglickém jazyce
Analysis of Current Unbalance in Meshed Transmission System
Popis výsledku anglicky
The paper describes new approach of the calculation of current unbalance in a meshed transmission system. The system is composed of several parts with different types of towers, phase sequence arrangements, types of conductors and one or two transmission lines on the same tower. The calculations are performed by dividing the problem to a number of impedance matrices respecting the mutual impedances between all conductors. In the examined transmission system there exist parts with different number of lines but the same number of shield wires. For connection of parts with two transmission lines and two shield wires to another part with one transmission line and two shield wires, virtual shield wires must be created to keep the continuity of the calculations. After current unbalance calculations, necessary steps must be taken to symmetrize the part of the transmission system examined. Due to requirement of changing phase sequence arrangement only in one part of our system, classical way of transposition based on line division into three parts and alternation of conductors between themselves cannot be used. All possible phase sequence arrangements in each transmission line of the part of the system are examined, the best solution must be then calculated and selected.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2015 16th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-4673-6788-2
ISSN
—
e-ISSN
2376-5623
Počet stran výsledku
5
Strana od-do
320-324
Název nakladatele
VŠB - Technical University of Ostrava
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou
Datum konání akce
20. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000377548600062