Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00239936" target="_blank" >RIV/68407700:21230/16:00239936 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21730/16:00239936
Výsledek na webu
<a href="https://www.degruyter.com/view/j/bmte.2016.61.issue-6/bmt-2015-0098/bmt-2015-0098.xml?format=INT" target="_blank" >https://www.degruyter.com/view/j/bmte.2016.61.issue-6/bmt-2015-0098/bmt-2015-0098.xml?format=INT</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/bmt-2015-0098" target="_blank" >10.1515/bmt-2015-0098</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff
Popis výsledku v původním jazyce
Systemic arterial blood pressure (BP) is one of the most important parameters of the cardiovascular system. An oscillometric NIBP monitor was specifically designed to measure oscillometric pulsations and mean arterial pressure (MAP) during inflation and deflation of the cuff. Nineteen healthy young (age 23.1±1.7 years; mean±SD) and 35 elderly (83.9±7.9 years; mean±SD) subjects were studied. Differential analysis of MAP during inflation and deflation show mean |ΔMAP|=2.9±2.6 mm Hg in the young group (mean±SD) and |ΔMAP|=6.3±5.2 mm Hg for seniors (mean±SD). There was a significant difference (p<0.05) in means of |ΔMAP| measured during cuff inflation and cuff deflation between both groups. In about 50% of elderly subjects |ΔMAP| was higher than 5 mm Hg. Potential clinical relevance of the method needs to be further evaluated.
Název v anglickém jazyce
Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff
Popis výsledku anglicky
Systemic arterial blood pressure (BP) is one of the most important parameters of the cardiovascular system. An oscillometric NIBP monitor was specifically designed to measure oscillometric pulsations and mean arterial pressure (MAP) during inflation and deflation of the cuff. Nineteen healthy young (age 23.1±1.7 years; mean±SD) and 35 elderly (83.9±7.9 years; mean±SD) subjects were studied. Differential analysis of MAP during inflation and deflation show mean |ΔMAP|=2.9±2.6 mm Hg in the young group (mean±SD) and |ΔMAP|=6.3±5.2 mm Hg for seniors (mean±SD). There was a significant difference (p<0.05) in means of |ΔMAP| measured during cuff inflation and cuff deflation between both groups. In about 50% of elderly subjects |ΔMAP| was higher than 5 mm Hg. Potential clinical relevance of the method needs to be further evaluated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedizinische Technik / Biomedical Engineering
ISSN
0013-5585
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
611-621
Kód UT WoS článku
000389468000006
EID výsledku v databázi Scopus
—