Microwave Hyperthermia System for Head and Neck Area with Noninvasive UWB Temperature Change Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F17%3A00315531" target="_blank" >RIV/68407700:21230/17:00315531 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PIERS.2017.8262015" target="_blank" >http://dx.doi.org/10.1109/PIERS.2017.8262015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PIERS.2017.8262015" target="_blank" >10.1109/PIERS.2017.8262015</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Microwave Hyperthermia System for Head and Neck Area with Noninvasive UWB Temperature Change Detection
Popis výsledku v původním jazyce
The main topic of this contribution is the design and demonstration of combination the hyperthermia applicator system for head and neck area working on frequency 434 MHz with UWB radar antenna array for differential temperature detection. For our numerical simulations, the simplified homogenous phantom and 3D numerical model of patient were used. For two-dimensional reconstruction of reflected signals the Delay and Sum beamforming algorithm were used. The phantom was locally heated up using the microwave hyperthermia applicator and the temperature distribution was used as an inhomogeneity (through change in relative permittivity and specific conductivity). The results confirm the feasibility and usability of temperature change detection via UWB signal in the head and neck area.
Název v anglickém jazyce
Microwave Hyperthermia System for Head and Neck Area with Noninvasive UWB Temperature Change Detection
Popis výsledku anglicky
The main topic of this contribution is the design and demonstration of combination the hyperthermia applicator system for head and neck area working on frequency 434 MHz with UWB radar antenna array for differential temperature detection. For our numerical simulations, the simplified homogenous phantom and 3D numerical model of patient were used. For two-dimensional reconstruction of reflected signals the Delay and Sum beamforming algorithm were used. The phantom was locally heated up using the microwave hyperthermia applicator and the temperature distribution was used as an inhomogeneity (through change in relative permittivity and specific conductivity). The results confirm the feasibility and usability of temperature change detection via UWB signal in the head and neck area.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GC17-20498J" target="_blank" >GC17-20498J: Neinvazivní určení teploty v lidském těle pomocí fyzikálních aspektů ultra-širokopásmového mikrovlnného kanálu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Progress In Electromagnetics Research Symposium 2017
ISBN
978-1-5090-6269-0
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
The Electromagnetics Academy
Místo vydání
Cambridge, MA
Místo konání akce
St. Petersburg
Datum konání akce
22. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—