Microwave MTM-based sensor for blood glucose concentration measurement: Sensitivity analysis by means of numerical simulations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F17%3A00321376" target="_blank" >RIV/68407700:21230/17:00321376 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/17:00321376
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PIERS-FALL.2017.8293451" target="_blank" >http://dx.doi.org/10.1109/PIERS-FALL.2017.8293451</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PIERS-FALL.2017.8293451" target="_blank" >10.1109/PIERS-FALL.2017.8293451</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Microwave MTM-based sensor for blood glucose concentration measurement: Sensitivity analysis by means of numerical simulations
Popis výsledku v původním jazyce
In this work two different models of dielectric properties of blood glucose solutions are used to evaluate metamaterial sensor sensitivity by means of numerical simulations. Model A is adopted from professional literature and the model B was created by our group using information about dielectric properties of blood plasma-glucose solutions, recently published dielectric properties of red blood cell cytoplasm-glucose solutions and an electromagnetic mixing formula. It can be concluded that the sensor shows smaller sensitivity for the model B than for the model A. Furthermore it shows due to non-linear dependency of dielectric properties on glucose concentration predicted by model B a lower sensitivity for high glucose concentrations
Název v anglickém jazyce
Microwave MTM-based sensor for blood glucose concentration measurement: Sensitivity analysis by means of numerical simulations
Popis výsledku anglicky
In this work two different models of dielectric properties of blood glucose solutions are used to evaluate metamaterial sensor sensitivity by means of numerical simulations. Model A is adopted from professional literature and the model B was created by our group using information about dielectric properties of blood plasma-glucose solutions, recently published dielectric properties of red blood cell cytoplasm-glucose solutions and an electromagnetic mixing formula. It can be concluded that the sensor shows smaller sensitivity for the model B than for the model A. Furthermore it shows due to non-linear dependency of dielectric properties on glucose concentration predicted by model B a lower sensitivity for high glucose concentrations
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ17-00477Y" target="_blank" >GJ17-00477Y: Fyzikální podstata interakcí EM pole generovaného MTM strukturami s lidským tělem a studie možnosti jejich perspektivního využití v medicíně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 39th PIERS in Singapore
ISBN
—
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1919-1923
Název nakladatele
The Electromagnetics Academy
Místo vydání
Cambridge, MA
Místo konání akce
Singapore
Datum konání akce
19. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000428518301173