Design of the Low Voltage Power Supply for Radio and Plasma Waves Investigation Instrument and ESA/JUICE Mission
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00322371" target="_blank" >RIV/68407700:21230/18:00322371 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ijastnet.com/journal/index/896" target="_blank" >http://www.ijastnet.com/journal/index/896</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.30845/ijast.v8n2a4" target="_blank" >10.30845/ijast.v8n2a4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of the Low Voltage Power Supply for Radio and Plasma Waves Investigation Instrument and ESA/JUICE Mission
Popis výsledku v původním jazyce
European Space Agency's selected Large-class mission called JUICE to study Jupiter and its icy moons environment will carry the Radio and Plasma Waves Investigation instrument aboard during more than 11 years long mission. It will characterize incident radio waves, perform multipoint in-situ plasma impedance measurements, carry triplet of search coil magnetometers and perform data preprocessing. Low Voltage Power Supply unit hereby presented have to deliver very low noisy stabilized power to sensitive instruments working from DC up to 45 MHz, distribute low jitter synchronization clock to respective subunits and provide with housekeeping telemetry measurements. It was designed to meet or exceed Total Ionizing Dose requirement of at least 50 kRad(Si).
Název v anglickém jazyce
Design of the Low Voltage Power Supply for Radio and Plasma Waves Investigation Instrument and ESA/JUICE Mission
Popis výsledku anglicky
European Space Agency's selected Large-class mission called JUICE to study Jupiter and its icy moons environment will carry the Radio and Plasma Waves Investigation instrument aboard during more than 11 years long mission. It will characterize incident radio waves, perform multipoint in-situ plasma impedance measurements, carry triplet of search coil magnetometers and perform data preprocessing. Low Voltage Power Supply unit hereby presented have to deliver very low noisy stabilized power to sensitive instruments working from DC up to 45 MHz, distribute low jitter synchronization clock to respective subunits and provide with housekeeping telemetry measurements. It was designed to meet or exceed Total Ionizing Dose requirement of at least 50 kRad(Si).
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Název periodika
International Journal of Applied Science and Technology
ISSN
2221-0997
e-ISSN
—
Svazek periodika
2018
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
24-35
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—