Numerical analysis of microwave tomography system for brain stroke detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00325044" target="_blank" >RIV/68407700:21230/18:00325044 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/18:00325044
Výsledek na webu
<a href="http://dx.doi.org/10.1109/RADIOELEK.2018.8376398" target="_blank" >http://dx.doi.org/10.1109/RADIOELEK.2018.8376398</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/RADIOELEK.2018.8376398" target="_blank" >10.1109/RADIOELEK.2018.8376398</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical analysis of microwave tomography system for brain stroke detection
Popis výsledku v původním jazyce
In this paper numerical analysis of a microwave tomography system for brain stroke detection is presented. This system is composed from octagonal container filled with liquid phantom having the average dielectric parameters of human head. On the walls of the container, there are eight slot bow tie antennas. This system was numerical modelled and evaluated. According to the analysis, modification in physical realization of the system can be considered and should lead to a better design of the future version. The analysis includes observation of distribution of E field inside of the container, evaluation of S parameter matrix and response of the system to a presence of a phantom of haemorrhagic stroke. Image reconstruction algorithm is finally applied on the S parameter matrix and the results of reconstruction are presented.
Název v anglickém jazyce
Numerical analysis of microwave tomography system for brain stroke detection
Popis výsledku anglicky
In this paper numerical analysis of a microwave tomography system for brain stroke detection is presented. This system is composed from octagonal container filled with liquid phantom having the average dielectric parameters of human head. On the walls of the container, there are eight slot bow tie antennas. This system was numerical modelled and evaluated. According to the analysis, modification in physical realization of the system can be considered and should lead to a better design of the future version. The analysis includes observation of distribution of E field inside of the container, evaluation of S parameter matrix and response of the system to a presence of a phantom of haemorrhagic stroke. Image reconstruction algorithm is finally applied on the S parameter matrix and the results of reconstruction are presented.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 28th International Conference Radioelektronika
ISBN
978-1-5386-2485-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE (Institute of Electrical and Electronics Engineers)
Místo vydání
—
Místo konání akce
Praha
Datum konání akce
19. 4. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—