Piezoelectric Lightning Current Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00327556" target="_blank" >RIV/68407700:21230/18:00327556 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Piezoelectric Lightning Current Detection
Popis výsledku v původním jazyce
This article discusses an alternative possibility of detecting lightning discharge strike at a lightning protection system, as compared with the classical sensors based on the inductive principle (using a coil) or the principles requiring external feed, such as the application of the Faraday optical transformer. The key advantage offered by our proposed system is its indirect method of evaluating the impacted lightning protection system, which is based on the piezoelectric principle. Other advantages of the proposed system include direct independence on the lightning current passing through the downconductor and thus a lower risk of damage to the sensor by the lightning current, and absolute independence of the inner installation and, therefore, elimination of any risks for its operators and users, as well as a lower risk of an electric discharge flashover and outbreak of fire in a given structure.
Název v anglickém jazyce
Piezoelectric Lightning Current Detection
Popis výsledku anglicky
This article discusses an alternative possibility of detecting lightning discharge strike at a lightning protection system, as compared with the classical sensors based on the inductive principle (using a coil) or the principles requiring external feed, such as the application of the Faraday optical transformer. The key advantage offered by our proposed system is its indirect method of evaluating the impacted lightning protection system, which is based on the piezoelectric principle. Other advantages of the proposed system include direct independence on the lightning current passing through the downconductor and thus a lower risk of damage to the sensor by the lightning current, and absolute independence of the inner installation and, therefore, elimination of any risks for its operators and users, as well as a lower risk of an electric discharge flashover and outbreak of fire in a given structure.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000481" target="_blank" >EF15_003/0000481: Centrum výzkumu kosmického záření a radiačních jevů v atmosféře</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů