Popis výsledku v původním jazyce
In this paper, temperature sensitivity of inductance position transducer of a pneumatic cylinder system is presented. The magnetic solid iron rod and aluminum piston position changes the inductance of the tubular coil around the aluminum pneumatic cylinder. The measurement and finite element method are used to evaluate inductances versus piston position at different frequencies. Temperature effect on the coil inductance is analyzed. Temperature of the iron rod and the aluminum cylinder are changed for the temperature sensitivity analysis. The measured iron rod temperature dependence is in the order of 0.45 %/°C at 100 Hz and 0.27 %/°C at 200 Hz. Finally a small compensating solenoid coil is used at one side of the cylinder (entrance side for piston) to compensate temperature dependency effects
Název v anglickém jazyce
Temperature Influence on Position Transducer for Pneumatic Cylinder
Popis výsledku anglicky
In this paper, temperature sensitivity of inductance position transducer of a pneumatic cylinder system is presented. The magnetic solid iron rod and aluminum piston position changes the inductance of the tubular coil around the aluminum pneumatic cylinder. The measurement and finite element method are used to evaluate inductances versus piston position at different frequencies. Temperature effect on the coil inductance is analyzed. Temperature of the iron rod and the aluminum cylinder are changed for the temperature sensitivity analysis. The measured iron rod temperature dependence is in the order of 0.45 %/°C at 100 Hz and 0.27 %/°C at 200 Hz. Finally a small compensating solenoid coil is used at one side of the cylinder (entrance side for piston) to compensate temperature dependency effects
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeding - 2018 IEEE SENSORS
ISBN
978-1-5386-4707-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE SENSORS
Místo vydání
—
Místo konání akce
Delhi
Datum konání akce
28. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—