Experimental load test statistics for the selected IPS tools on low-performance IoT devices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00333777" target="_blank" >RIV/68407700:21230/19:00333777 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.2478/jee-2019-0058" target="_blank" >https://doi.org/10.2478/jee-2019-0058</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/jee-2019-0058" target="_blank" >10.2478/jee-2019-0058</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental load test statistics for the selected IPS tools on low-performance IoT devices
Popis výsledku v původním jazyce
The goal of this paper is to propose a testing procedure for selected Intrusion Prevention Systems (IPS) in a realistic network traffic in terms of their suitability on a given hardware microcomputers for low-performance devices for Internet ofThings (IoT). We perform an IPS research in terms of resource usage in order to establish a universal procedure of checking,whether a given microcomputer controlling IoT devices (often in overloaded state) can additionally burden the installation and start-up of IPS. The experiment is repeated on several boards under overload condition to determine the maximum data rate, above which transmission degrades. The presented testing method is an exemplary tool for IoT applications concerning the security of embedded devices with low performance.
Název v anglickém jazyce
Experimental load test statistics for the selected IPS tools on low-performance IoT devices
Popis výsledku anglicky
The goal of this paper is to propose a testing procedure for selected Intrusion Prevention Systems (IPS) in a realistic network traffic in terms of their suitability on a given hardware microcomputers for low-performance devices for Internet ofThings (IoT). We perform an IPS research in terms of resource usage in order to establish a universal procedure of checking,whether a given microcomputer controlling IoT devices (often in overloaded state) can additionally burden the installation and start-up of IPS. The experiment is repeated on several boards under overload condition to determine the maximum data rate, above which transmission degrades. The presented testing method is an exemplary tool for IoT applications concerning the security of embedded devices with low performance.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20202 - Communication engineering and systems
Návaznosti výsledku
Projekt
<a href="/cs/project/TJ01000182" target="_blank" >TJ01000182: Vývoj sondy pro preventivní ochranu IoT zařízení před pokusy o jejich převzetí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electrical Engineering
ISSN
1335-3632
e-ISSN
1339-309X
Svazek periodika
70
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
10
Strana od-do
285-294
Kód UT WoS článku
000495458200003
EID výsledku v databázi Scopus
2-s2.0-85074685621