Stabilized-load crystal oscillator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00335457" target="_blank" >RIV/68407700:21230/19:00335457 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/10467/87103" target="_blank" >http://hdl.handle.net/10467/87103</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stabilized-load crystal oscillator
Popis výsledku v původním jazyce
The presence and concentration of some gases can be sensed by quartz crystal resonators covered by a thin layer of gas-absorbing material. The absorbed gas increases the inertial mass of the layer, and as a result the resonating frequency of the crystal is changed. However, a disadvantage of this method lies in the fact that the absorbed mass increases internal friction in the sensing layer, leading to increased damping, in other words dropping the Q-factor of the resonator. If the resonating frequency is to be measured by using the resonator as the frequency-determining device of an autonomous oscillator, accuracy problems appear due to the wide variations of the resonator Q-factor. The following article shows effective patented methods diminishing this problem.
Název v anglickém jazyce
Stabilized-load crystal oscillator
Popis výsledku anglicky
The presence and concentration of some gases can be sensed by quartz crystal resonators covered by a thin layer of gas-absorbing material. The absorbed gas increases the inertial mass of the layer, and as a result the resonating frequency of the crystal is changed. However, a disadvantage of this method lies in the fact that the absorbed mass increases internal friction in the sensing layer, leading to increased damping, in other words dropping the Q-factor of the resonator. If the resonating frequency is to be measured by using the resonator as the frequency-determining device of an autonomous oscillator, accuracy problems appear due to the wide variations of the resonator Q-factor. The following article shows effective patented methods diminishing this problem.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of IWSSIP 2019
ISBN
978-1-7281-3227-3
ISSN
2157-8672
e-ISSN
—
Počet stran výsledku
4
Strana od-do
35-38
Název nakladatele
FEE, Computer Science and Information Technology, Osijek
Místo vydání
Osijek
Místo konání akce
Osijek
Datum konání akce
5. 7. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000501745100004