Impact of Defective Modules on the Characteristics of a Large-Scale Grid-Connected PV Power Plant
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00338409" target="_blank" >RIV/68407700:21230/19:00338409 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4229/EUPVSEC20192019-5CV.4.42" target="_blank" >http://dx.doi.org/10.4229/EUPVSEC20192019-5CV.4.42</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4229/EUPVSEC20192019-5CV.4.42" target="_blank" >10.4229/EUPVSEC20192019-5CV.4.42</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Impact of Defective Modules on the Characteristics of a Large-Scale Grid-Connected PV Power Plant
Popis výsledku v původním jazyce
The effect of the connection of different, shaded or damaged module on the performance of the whole string or the photovoltaic (PV) panel connected to a single inverter is very often discussed. Although there exist the means for protecting the PV system against negative influence of connecting PV modules with different parameters into one system (diodes, power optimizers), the real impact is not examined anymore. The simulation tools presume the connection of the same module type with same parameters and the differences are discussed only theoretically. The simulations performed in the SPICE program rather indicate that with less damage, one different module should not have a significant effect on the power drop, even in the theoretical case that no bypass diode is included in the string. The results of simulation as well as the measurement on the real system with modules with different parameters are presented in this work.
Název v anglickém jazyce
Impact of Defective Modules on the Characteristics of a Large-Scale Grid-Connected PV Power Plant
Popis výsledku anglicky
The effect of the connection of different, shaded or damaged module on the performance of the whole string or the photovoltaic (PV) panel connected to a single inverter is very often discussed. Although there exist the means for protecting the PV system against negative influence of connecting PV modules with different parameters into one system (diodes, power optimizers), the real impact is not examined anymore. The simulation tools presume the connection of the same module type with same parameters and the differences are discussed only theoretically. The simulations performed in the SPICE program rather indicate that with less damage, one different module should not have a significant effect on the power drop, even in the theoretical case that no bypass diode is included in the string. The results of simulation as well as the measurement on the real system with modules with different parameters are presented in this work.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000464" target="_blank" >EF15_003/0000464: Centrum pokročilé fotovoltaiky</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EU PVSEC 2019 Proceedings
ISBN
978-3-936338-60-7
ISSN
—
e-ISSN
2196-100X
Počet stran výsledku
3
Strana od-do
1667-1669
Název nakladatele
WIP - Renewable Energies
Místo vydání
Munich
Místo konání akce
Marseille
Datum konání akce
9. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—