Non-contact Monitoring of Respiration and Heart Activity of Infants Using UWB Signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00340896" target="_blank" >RIV/68407700:21230/19:00340896 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/19:00340896
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017595" target="_blank" >http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017595</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PIERS-Spring46901.2019.9017595" target="_blank" >10.1109/PIERS-Spring46901.2019.9017595</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non-contact Monitoring of Respiration and Heart Activity of Infants Using UWB Signals
Popis výsledku v původním jazyce
The main purpose of this contribution is to introduce a new system which is able to simultaneously to monitor the breathing and heart activity of an infant. The working frequency band of the system is 1 - 8 GHz. Three bow-tie antennas (1 transmitter Tx and 2 receivers Rx) are placed over the neonatal. The antennas are placed 60 cm above the infant. In case of measurement the Tx antenna is emitting the UWB signal, which is reflected from the body and detected by the Rx antennas. The static background is subtracted by the signal mean value. The detection principle is based on the knowledge that the respiratory frequency of an infant (1 - 3 years old) is around 1 Hz and the movement of the chest is about 0.2 mm. This can be detected via UWB radar as peak detection and its movement caused by breathing. In case of infants' apnea, we propose a dynamic threshold. From the signal it is also possible to detect the heart activity.
Název v anglickém jazyce
Non-contact Monitoring of Respiration and Heart Activity of Infants Using UWB Signals
Popis výsledku anglicky
The main purpose of this contribution is to introduce a new system which is able to simultaneously to monitor the breathing and heart activity of an infant. The working frequency band of the system is 1 - 8 GHz. Three bow-tie antennas (1 transmitter Tx and 2 receivers Rx) are placed over the neonatal. The antennas are placed 60 cm above the infant. In case of measurement the Tx antenna is emitting the UWB signal, which is reflected from the body and detected by the Rx antennas. The static background is subtracted by the signal mean value. The detection principle is based on the knowledge that the respiratory frequency of an infant (1 - 3 years old) is around 1 Hz and the movement of the chest is about 0.2 mm. This can be detected via UWB radar as peak detection and its movement caused by breathing. In case of infants' apnea, we propose a dynamic threshold. From the signal it is also possible to detect the heart activity.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GC17-20498J" target="_blank" >GC17-20498J: Neinvazivní určení teploty v lidském těle pomocí fyzikálních aspektů ultra-širokopásmového mikrovlnného kanálu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium
ISBN
9781728134031
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
4
Strana od-do
2534-2537
Název nakladatele
Institute of Electrical and Electronics Engineers, Inc.
Místo vydání
—
Místo konání akce
Řím
Datum konání akce
17. 6. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000550769302086