1-pT noise fluxgate magnetometer for geomagnetic measurements and unshielded magnetocardiography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00334308" target="_blank" >RIV/68407700:21230/20:00334308 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/TIM.2019.2949205" target="_blank" >https://doi.org/10.1109/TIM.2019.2949205</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TIM.2019.2949205" target="_blank" >10.1109/TIM.2019.2949205</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
1-pT noise fluxgate magnetometer for geomagnetic measurements and unshielded magnetocardiography
Popis výsledku v původním jazyce
We present the development of a low-noise, fundamental-mode, orthogonal fluxgate magnetometer with four amorphous, annealed ferromagnetic wires. The 1-Hz noise obtained in open-loop and closed-loop is as low as 0.75 and 1.5 pTrms/root Hz, respectively, with white noise level about 0.6 pTrms/root Hz. This is to our knowledge the lowest figure published for a fluxgate magnetometer so far. We compared the instrument performance to a low-noise observatory magnetometer when doing geomagnetic measurements and show that it is fully suitable for measurements at mHz frequencies, e.g. magnetotellurics. The magnetometer performance enables room-temperature, unshielded magnetocardiography.
Název v anglickém jazyce
1-pT noise fluxgate magnetometer for geomagnetic measurements and unshielded magnetocardiography
Popis výsledku anglicky
We present the development of a low-noise, fundamental-mode, orthogonal fluxgate magnetometer with four amorphous, annealed ferromagnetic wires. The 1-Hz noise obtained in open-loop and closed-loop is as low as 0.75 and 1.5 pTrms/root Hz, respectively, with white noise level about 0.6 pTrms/root Hz. This is to our knowledge the lowest figure published for a fluxgate magnetometer so far. We compared the instrument performance to a low-noise observatory magnetometer when doing geomagnetic measurements and show that it is fully suitable for measurements at mHz frequencies, e.g. magnetotellurics. The magnetometer performance enables room-temperature, unshielded magnetocardiography.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
1557-9662
Svazek periodika
69
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
2552-2560
Kód UT WoS článku
000528560200026
EID výsledku v databázi Scopus
2-s2.0-85083230840