Lightning incidence on transmission overhead lines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00345657" target="_blank" >RIV/68407700:21230/20:00345657 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/EPE51172.2020.9269198" target="_blank" >https://doi.org/10.1109/EPE51172.2020.9269198</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE51172.2020.9269198" target="_blank" >10.1109/EPE51172.2020.9269198</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lightning incidence on transmission overhead lines
Popis výsledku v původním jazyce
The paper deals with an estimation of lightning strike incidence to transmission overhead lines in the context of line outages gathered from an automatic monitoring system. The statistics of the Czech transmission system's line outages caused by lightning strikes are presented and analyzed. Lines with significantly higher outage rates are identified, and the electrogeometric model is used for lightning incidence calculation. The estimation that the lightning strikes the phase conductor, ground wire, or tower constructions of overhead line is performed. Finally, the ratio of lightning strikes that caused line outage to the total number of lightning strikes to phase conductors is evaluated and compared with the values obtained from the monitoring system.
Název v anglickém jazyce
Lightning incidence on transmission overhead lines
Popis výsledku anglicky
The paper deals with an estimation of lightning strike incidence to transmission overhead lines in the context of line outages gathered from an automatic monitoring system. The statistics of the Czech transmission system's line outages caused by lightning strikes are presented and analyzed. Lines with significantly higher outage rates are identified, and the electrogeometric model is used for lightning incidence calculation. The estimation that the lightning strikes the phase conductor, ground wire, or tower constructions of overhead line is performed. Finally, the ratio of lightning strikes that caused line outage to the total number of lightning strikes to phase conductors is evaluated and compared with the values obtained from the monitoring system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2020 21st International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-7281-9479-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Czechoslovakia Section IEEE
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
19. 10. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—