Calibration of unipolar high current impulses for resistance spot welding
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00345664" target="_blank" >RIV/68407700:21230/20:00345664 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/EPE51172.2020.9269221" target="_blank" >https://doi.org/10.1109/EPE51172.2020.9269221</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE51172.2020.9269221" target="_blank" >10.1109/EPE51172.2020.9269221</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration of unipolar high current impulses for resistance spot welding
Popis výsledku v původním jazyce
Requirement from practice is the need for quality and precise measurement of unipolar high current impulses, which are applied in resistance spot welding. The reason is the high dependence of weld quality on the shape and energy of applied current impulses. A new calibration method for this current impulses without disconnecting the current circuit of a resistance welding machine is required. Review and selection of suitable noninvasive current sensing devices have been made. Frequency analysis of typical unipolar current welding impulses was performed as well. The following measurements of chosen sensing devices with Hall sensors and special magnetoresistance sensor verified the necessary frequency bandwidth of the sensors. Verification measurements of unipolar current impulses were carried out as well. Finally, the uncertainty of the calibration method with a noninvasive current sensing device has been determined.
Název v anglickém jazyce
Calibration of unipolar high current impulses for resistance spot welding
Popis výsledku anglicky
Requirement from practice is the need for quality and precise measurement of unipolar high current impulses, which are applied in resistance spot welding. The reason is the high dependence of weld quality on the shape and energy of applied current impulses. A new calibration method for this current impulses without disconnecting the current circuit of a resistance welding machine is required. Review and selection of suitable noninvasive current sensing devices have been made. Frequency analysis of typical unipolar current welding impulses was performed as well. The following measurements of chosen sensing devices with Hall sensors and special magnetoresistance sensor verified the necessary frequency bandwidth of the sensors. Verification measurements of unipolar current impulses were carried out as well. Finally, the uncertainty of the calibration method with a noninvasive current sensing device has been determined.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2020 21st International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-7281-9479-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Czechoslovakia Section IEEE
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
19. 10. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce