The effects of interventional mitral valve repair using the MitraClip System on the results of pulmonary function testing, pulmonary pressure and diffusing capacity of the lung
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F21%3A00354521" target="_blank" >RIV/68407700:21230/21:00354521 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1186/s12872-021-02042-1" target="_blank" >https://doi.org/10.1186/s12872-021-02042-1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12872-021-02042-1" target="_blank" >10.1186/s12872-021-02042-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The effects of interventional mitral valve repair using the MitraClip System on the results of pulmonary function testing, pulmonary pressure and diffusing capacity of the lung
Popis výsledku v původním jazyce
The study analyzes changes in lung function, pulmonary pressure and diffusing capacity of the lung in patients with mitral valve regurgitation (MR) treated by MitraClip implantation. A total of 43 patients (19 women and 24 men with an average age of 78.0 ± 6.6 years) who were able to perform pulmonary function testing including diffusing capacity of the lung for carbon monoxide (DLCO), vital capacity (VC), total lung capacity (TLC), residual volume (RV) and forced expiratory volume in 1 s (FEV1) before and 6 weeks after MitraClip implantation participated in this study. Furthermore, clinical and echocardiographic parameters including systolic pulmonary artery pressure (sPAP), left ventricular ejection fraction (LVEF) and left atrial diameter (LAD) measurements were recorded in all patients. The procedure was performed successfully in all 43 patients leading to a reduction of MR in 97.7% of cases. One patient died on day 4 after the intervention most likely due to pulmonary artery embolism. Six weeks after the implantation 79.1% of patients showed a MR of at most mild to moderate. Furthermore, we could demonstrate a significant reduction of systolic pulmonary artery pressure during follow-up (from 48.8 ± 11.4 mmHg to 42.9 ± 9.0 mmHg (t(41) = - 2.6, p = 0.01). However, no changes in LVEF were detected. Comparing pre and post implant lung function tests, no significant alterations were seen for VC, TLC, DLCO and FEV1. Though, in a subgroup of patients with moderate to severe preexisting deterioration of DLCO at the baseline (max. 50%) the MitraClip procedure resulted in a significant improvement in DLCO (37.8% ± 9.0 to 41.6% ± 10.0, p < 0.001). Treatment of MR with the MitraClip system successfully reduces MR severity in the vast majority of patients. Consecutively, a reduction in pulmonary pressure could be observed, however no changes in LVEF were obvious. Lung function tests remained unaltered during follow-up. [...]
Název v anglickém jazyce
The effects of interventional mitral valve repair using the MitraClip System on the results of pulmonary function testing, pulmonary pressure and diffusing capacity of the lung
Popis výsledku anglicky
The study analyzes changes in lung function, pulmonary pressure and diffusing capacity of the lung in patients with mitral valve regurgitation (MR) treated by MitraClip implantation. A total of 43 patients (19 women and 24 men with an average age of 78.0 ± 6.6 years) who were able to perform pulmonary function testing including diffusing capacity of the lung for carbon monoxide (DLCO), vital capacity (VC), total lung capacity (TLC), residual volume (RV) and forced expiratory volume in 1 s (FEV1) before and 6 weeks after MitraClip implantation participated in this study. Furthermore, clinical and echocardiographic parameters including systolic pulmonary artery pressure (sPAP), left ventricular ejection fraction (LVEF) and left atrial diameter (LAD) measurements were recorded in all patients. The procedure was performed successfully in all 43 patients leading to a reduction of MR in 97.7% of cases. One patient died on day 4 after the intervention most likely due to pulmonary artery embolism. Six weeks after the implantation 79.1% of patients showed a MR of at most mild to moderate. Furthermore, we could demonstrate a significant reduction of systolic pulmonary artery pressure during follow-up (from 48.8 ± 11.4 mmHg to 42.9 ± 9.0 mmHg (t(41) = - 2.6, p = 0.01). However, no changes in LVEF were detected. Comparing pre and post implant lung function tests, no significant alterations were seen for VC, TLC, DLCO and FEV1. Though, in a subgroup of patients with moderate to severe preexisting deterioration of DLCO at the baseline (max. 50%) the MitraClip procedure resulted in a significant improvement in DLCO (37.8% ± 9.0 to 41.6% ± 10.0, p < 0.001). Treatment of MR with the MitraClip system successfully reduces MR severity in the vast majority of patients. Consecutively, a reduction in pulmonary pressure could be observed, however no changes in LVEF were obvious. Lung function tests remained unaltered during follow-up. [...]
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BMC Cardiovascular Disorders
ISSN
1471-2261
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
235
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000649382100001
EID výsledku v databázi Scopus
2-s2.0-85105628524